Analisis Pengaruh Jarak dan Posisi Lubang Rivet Sambungan Tumpuk Terhadap Kekuatan dan Faktor Keamanan

  • Aldi Tio Nugraha Universitas Singaperbangsa Karawang

Abstract

Connection with plates by stacking them using rivets is generally used in construction or machine parts that have different materials. Failures that occur in these connections are generally in the plate holes that are connected to one another. The vertical or horizontal distance of the hole diameter that does not match is the cause of the failure. From the research I conducted on the pile connection model using the Ansys application, it is known that the plate riveted connection with an axial load of 20 N. The riveted stack connection will be safe at the distance between vertical holes L = 32 mm and horizontal C = 32 mm. The stress that occurs at 275.75 MPa is much smaller than at other distances. In terms of the factor of safety that occurs for the distances L and C mentioned above, it gives a safe value of 1.37.

References

Popov, E, P, dan Astamar Zainul, ”Mekanika Teknik”, Edisi kedua Penerbit Erlangga, Jakarta, 1991.

Shigley, Joseph and Mischke, Charles, “Standard Handbook of Machine Design”, Second Edition, Mic Graw Hill, NY, 1996

Spotts, F, M, “ Design Of Machine Elements” Third Edition, Prentice-Hall inc, England.

Suga, Kiyokatsu dan Sularso, “Dasar Perencanaan dan Pemilihan Elemen Mesin” Cetakan kesebelas, PT. Pradnya Paramita, Jakarta, 2013

Published
2023-01-24
How to Cite
Nugraha, A. (2023). Analisis Pengaruh Jarak dan Posisi Lubang Rivet Sambungan Tumpuk Terhadap Kekuatan dan Faktor Keamanan. Jurnal Ilmiah Wahana Pendidikan, 9(2), 31-39. https://doi.org/10.5281/zenodo.7563524