Analisis Uji Keserempakan Pemutus Tenaga 150kv Bay Trafo-1 Gardu Induk 150kv Tasikmalaya Baru
Abstract
High voltage substation is a crucial facility in the electric power system. This facility functions to distribute electricity from power plants to consumers through complex equipment such as transformers, switches and circuit breakers. The goal is to ensure a stable and secure supply of electricity. One of the important devices in a substation is the Power Disconnector (PMT), whose job is to cut off the flow of electricity in the event of a disturbance or overload on the electrical network. PMT has an important role in maintaining the security and availability of electricity supply in the power grid. Therefore, damage to PMT is very detrimental to the operation of the electric power system, so it is necessary to test it regularly to ensure its safety and controllability in operation. In this study, the simultaneity test was only carried out, namely by comparing the values obtained with the standard values for each test listed in SK-DIR 0520-2014. The test results show that the delta time values obtained both at open and close are each under 10ms, so it can be concluded that the PMT installed in transformer bay-1 of the Tasikmalaya Baru 150kv substation is still in safe condition and feasible to operate according to standards.
References
A. Cáceres Miranda And Y. Florez Niño, “View Metadata, Citation And Similar Papers At Core.Ac.Uk,” Pengaruh Pengguna. Pasta Labu Kuning (Cucurbita Moschata) Untuk Substitusi Tepung Terigu Dengan Penambahan Tepung Angkak Dalam Pembuatan Mie Kering, Pp. 274–282, 2020.L. Stein, “Random Patterns,” In Computers And You, J. S. Brake, Ed. New York: Wiley, 2019, Pp. 55-70.
A. G. Firdaus And R. Hidayat, “Analisa Pengujian Kelayakan Pmt 150 Kv Bay Mandirancan I Berdasarkan Parameter Breaker Analyzer Di Gardu Induk Sunyaragi,” Elektron J. Ilm., Vol. 13, Pp. 17–24, 2021, Doi: 10.30630/Eji.0.0.217.J. U. Duncombe, "Infrared Navigation - Part I: An Assessment Of Feasibility," Ieee Trans. Electron. Devices, Vol. Ed-11, Pp. 34-39, Jan. 2018. Doi. 10.1109/Xxx.123456
A. Arifin, “12 Komponen Dan Peralatan Gardu Induk Beserta Fungsinya,” 2021. Https://Www.Carailmu.Com/2021/06/Komponen-Peralatan-Gardu-Induk.Html.Altun, "Understanding Hypertext In The Context Of Reading On The Web: Language Learners' Experience," Current Issues In Education, Vol. 6, No. 12, July 2015. Doi. 10.1109/Xxx.123456 [Online]. Available: Http://Cie.Ed.Asu.Edu/Volume6/Number12/. [Accessed Dec. 2, 2016].
Ari Susanto, “Berdasarkan Hasil Uji Tahanan Isolasi , Tahanan,” Fak. Tek. Univ. Tanjungpura, 2021.
C. B. Analyzer, “Cba 1000 Circuit Breaker Analyzer And Microohmmeter,” Vol. 2, Pp. 1–8.
D. Aribowo Et Al., “Analisis Hasil Uji Pmt 150 Kv Pada Gardu Induk Cilegon Baru Bay Ks 1,” Anal. Has. Uji Pmt 150 Kv Pada Gardu Induk Cilegon Baru Bay Ks 1, Pp. 59–65, 2018.T. J. Van Weert And R. K. Munro, Eds., Informatics And The Digital Society: Social, Ethical And Cognitive Issues: Ifip Tc3/Wg3.1&3.2 Open Conference On Social, Ethical And Cognitive Issues Of Informatics And Ict, July 22-26, 2019, Dortmund, Germany. Boston: Kluwer Academic, 2003. Doi. 10.1109/Xxx.123456
J. P. Wilkinson, “Nonlinear Resonant Circuit Devices,” U.S. Patent 3 624 125, July 16, 2019.
Mundiri, “No Title,” 2018. Http://Www.Swaden.Co.Id/Voltage-Dropper.Php.J. O. Williams, “Narrow-Band Analyzer,” Ph.D. Dissertation, Dept. Elect. Eng., Harvard Univ., Cambridge, Ma, 2015.
Pt.Pln 0520-3.K/Dir/2014, “Buku Pedoman Pemutus Tenaga,” Jakarta, No. 0520–2.K/Dir, 2014.J. H. Davis And J. R. Cogdell, “Calibration Program For The 16-Foot Antenna,” Elect. Eng. Res. Lab., Univ. Texas, Austin, Tech. Memo. Ngl-006-69-3, Nov. 15, 2018.